<?xml version="1.0" standalone="yes"?>
<FractionTreatmentDataSet xmlns="BDAL/HyStar/FractionTreatmentDataSet.xsd">
  <Method Author="Dominic Kurian" Comment="" DataAcqRunTime="97" StartDelay="0" HyStarVersion="3.2.44.0" ComputerName="RII-115145" xmlns="" />
  <TimeTable Function="FlowRate" Time="0" DeviceType="Pump" DeviceNumber="1" xmlns="">
    <TableValues Value="0.02" />
  </TimeTable>
  <TimeTable Function="SolventMix" Time="0" DeviceType="Pump" DeviceNumber="1" xmlns="">
    <TableValues Value="100" />
    <TableValues Value="0" />
    <TableValues Value="0" />
    <TableValues Value="0" />
  </TimeTable>
  <Signal SlopeThreshold="0" ID="0" FullName="TIC,All" SmoothingWidth="2" Slope="20" Sensitivity="5" DeviceType="MassSpec" DeviceNumber="1" xmlns="" />
  <Signal SlopeThreshold="0" ID="1" FullName="BPC,All" SmoothingWidth="2" Slope="20" Sensitivity="5" PeakParam="5" DeviceType="MassSpec" DeviceNumber="1" MinPoints="20" xmlns="" />
  <Signal SlopeThreshold="0" ID="4" SmoothingWidth="2" Slope="20" Sensitivity="5" DeviceType="None" DeviceNumber="0" xmlns="" />
  <Detector SliceWidth="5" AutoZero="0" InvertSignal="0" Offset="0" DataChannel="1" DoReference="false" ReferenceStart="254" ReferenceWidth="10" SpecStart="190" SpecEnd="1200" DoSaveSpectra="true" SaveInterval="1" SaveType="1" DeviceNumber="1" xmlns="" />
  <Pump MinPressure="0" MaxPressure="500" Start="false" Runtime="97" DeviceNumber="1" xmlns="" />
  <Solvent ID="0" DeviceType="Pump" DeviceNumber="1" xmlns="" />
  <Solvent ID="1" DeviceType="Pump" DeviceNumber="1" xmlns="" />
  <Solvent ID="2" DeviceType="Pump" DeviceNumber="1" xmlns="" />
  <Solvent ID="3" DeviceType="Pump" DeviceNumber="1" xmlns="" />
  <ExtendedParameters DeviceFullName="Dionex System	SYSTEM1	SYSTEM	" Parameter="&lt;?xml version=&quot;1.0&quot; encoding=&quot;windows-1252&quot;?&gt; &#xD;&#xA;&#xD;&#xA;&lt;root&gt;&#xD;&#xA;    &lt;HyStarInfo ModuleName=&quot;Dionex System&quot; StyleSheet=&quot;NoStyleSheet.xls&quot; MethodName = &quot;PGM::\RII-115145_local\NCS3500RS\TempPgm&quot;&gt;&#xD;&#xA;&#xD;&#xA;	&lt;MethodData TotalRunTime=&quot;97.000000&quot; AcqDelay=&quot;0.000000&quot; AcqTime=&quot;0.000000&quot; Flow=&quot;0.020000&quot;&gt;&#xD;&#xA;	     &#xD;&#xA;        &#xD;&#xA;	&lt;/MethodData&gt;&#xD;&#xA;&#xD;&#xA;    &lt;/HyStarInfo&gt;&#xD;&#xA;&#xD;&#xA;    &lt;ModuleInfo Value=&quot;&quot;&gt; &#xD;&#xA;		;Initialize all Hystar synchronisation properties to 0.&#xD;&#xA;	ReadyToRun = 	0&#xD;&#xA;	DoInject = 	0&#xD;&#xA;	InjectResponse = 	0&#xD;&#xA;	Sampler.TempCtrl = 	On&#xD;&#xA;	Sampler.Temperature.Nominal = 	8.0 [°C]&#xD;&#xA;	Sampler.Temperature.LowerLimit = 	4.0 [°C]&#xD;&#xA;	Sampler.Temperature.UpperLimit = 	45.0 [°C]&#xD;&#xA;	Sampler.ReadyTempDelta = 	4.0 [°C]&#xD;&#xA;	ColumnOven.TempCtrl = 	On&#xD;&#xA;	ColumnOven.Temperature.Nominal = 	50.0 [°C]&#xD;&#xA;	ColumnOven.Temperature.LowerLimit = 	20.0 [°C]&#xD;&#xA;	ColumnOven.Temperature.UpperLimit = 	75.0 [°C]&#xD;&#xA;	EquilibrationTime = 	0.5 [min]&#xD;&#xA;	ColumnOven.ReadyTempDelta = 	5.0 [°C]&#xD;&#xA;	LoadingPump.Pressure.LowerLimit = 	0 [bar]&#xD;&#xA;	LoadingPump.Pressure.UpperLimit = 	496 [bar]&#xD;&#xA;	LoadingPump.MaximumFlowRampDown = 	499 [µl/min²]&#xD;&#xA;	LoadingPump.MaximumFlowRampUp = 	101 [µl/min²]&#xD;&#xA;	LoadingPump.%A.Equate = 	&quot;%A&quot;&#xD;&#xA;	LoadingPump.%B.Equate = 	&quot;%B&quot;&#xD;&#xA;	%C.Equate = 	&quot;%C&quot;&#xD;&#xA;	NC_Pump.Pressure.LowerLimit = 	0 [bar]&#xD;&#xA;	NC_Pump.Pressure.UpperLimit = 	750 [bar]&#xD;&#xA;	NC_Pump.MaximumFlowRampDown = 	99.996 [µl/min²]&#xD;&#xA;	NC_Pump.MaximumFlowRampUp = 	9.996 [µl/min²]&#xD;&#xA;	NC_Pump.%A.Equate = 	&quot;%A&quot;&#xD;&#xA;	NC_Pump.%B.Equate = 	&quot;%B&quot;&#xD;&#xA;	DrawSpeed = 	300 [nl/s]&#xD;&#xA;	DrawDelay = 	3000 [ms]&#xD;&#xA;	DispSpeed = 	4000 [nl/s]&#xD;&#xA;	DispenseDelay = 	2000 [ms]&#xD;&#xA;	WasteSpeed = 	8000 [nl/s]&#xD;&#xA;	WashSpeed = 	4000 [nl/s]&#xD;&#xA;	LoopWashFactor = 	2.000&#xD;&#xA;	SampleHeight = 	2.000 [mm]&#xD;&#xA;	PunctureDepth = 	10.000 [mm]&#xD;&#xA;	WashVolume = 	100.000 [µl]&#xD;&#xA;	RinseBetweenReinjections = 	No&#xD;&#xA;	LowDispersionMode = 	Off&#xD;&#xA;	InjectMode = 	ulPickUp&#xD;&#xA;	FirstTransportVial = 	R1&#xD;&#xA;	LastTransportVial = 	R1&#xD;&#xA;	TransportVialCapacity = 	Unlimited&#xD;&#xA;	TransLiquidHeight = 	11.000 [mm]&#xD;&#xA;	TransVialPunctureDepth = 	7.000 [mm]&#xD;&#xA;	FlushVolume = 	3.000 [µl]&#xD;&#xA;	LoadingPump_Pressure.Step = 	0.5&#xD;&#xA;	LoadingPump_Pressure.Average = 	Off&#xD;&#xA;	NC_Pump_Pressure.Step = 	0.01 [s]&#xD;&#xA;	NC_Pump_Pressure.Average = 	Off&#xD;&#xA;	NC_Pump_Press_RightBlk.Step = 	0.01 [s]&#xD;&#xA;	NC_Pump_Press_RightBlk.Average = 	Off&#xD;&#xA;	NC_Pump_Press_LeftBlk.Step = 	0.01 [s]&#xD;&#xA;	NC_Pump_Press_LeftBlk.Average = 	Off&#xD;&#xA;	ColumnOven_Temp.Step = 	0.01 [s]&#xD;&#xA;	ColumnOven_Temp.Average = 	Off&#xD;&#xA;	LoadingPump.Flow = 	20.000 [µl/min]&#xD;&#xA;	LoadingPump.%B = 	0.0 [%]&#xD;&#xA;	%C = 	0.0 [%]&#xD;&#xA;	ValveLeft = 	1_2&#xD;&#xA;&#xD;&#xA; 0.000	Wait	LoadingPump.Ready and NC_Pump.Ready and ColumnOven.Ready and Sampler.Ready and PumpModule.Ready&#xD;&#xA;	;Chromeleon sets this property to signal to Hystar that it is ready to start a run.&#xD;&#xA;	ReadyToRun = 	1&#xD;&#xA;	NC_Pump.Flow = 	0.400 [µl/min]&#xD;&#xA;	NC_Pump.%B = 	5.0 [%]&#xD;&#xA;	NC_Pump.Curve = 	5&#xD;&#xA;	;Hystar sets this property to start the injection.&#xD;&#xA;	Wait	DoInject&#xD;&#xA;	Wait	LoadingPump.Ready and NC_Pump.Ready and ColumnOven.Ready and Sampler.Ready and PumpModule.Ready&#xD;&#xA;	Inject&#xD;&#xA;	;Chromeleon sets this property to signal the injection to Hystar.&#xD;&#xA;	InjectResponse = 	1&#xD;&#xA;	LoadingPump_Pressure.AcqOn&#xD;&#xA;	NC_Pump_Pressure.AcqOn&#xD;&#xA;	NC_Pump_Press_RightBlk.AcqOn&#xD;&#xA;	NC_Pump_Press_LeftBlk.AcqOn&#xD;&#xA;	ColumnOven_Temp.AcqOn&#xD;&#xA;	NC_Pump.Flow = 	0.400 [µl/min]&#xD;&#xA;	NC_Pump.%B = 	5.0 [%]&#xD;&#xA;	NC_Pump.Curve = 	5&#xD;&#xA;&#xD;&#xA; 1.000	NC_Pump.Flow = 	0.400 [µl/min]&#xD;&#xA;	NC_Pump.%B = 	5.0 [%]&#xD;&#xA;	NC_Pump.Curve = 	5&#xD;&#xA;&#xD;&#xA; 4.000	ValveLeft = 	6_1&#xD;&#xA;&#xD;&#xA;60.000	&#xD;&#xA;	LoadingPump_Pressure.AcqOff&#xD;&#xA;	NC_Pump_Pressure.AcqOff&#xD;&#xA;	NC_Pump_Press_RightBlk.AcqOff&#xD;&#xA;	NC_Pump_Press_LeftBlk.AcqOff&#xD;&#xA;	ColumnOven_Temp.AcqOff&#xD;&#xA;	NC_Pump.Flow = 	0.400 [µl/min]&#xD;&#xA;	NC_Pump.%B = 	32.0 [%]&#xD;&#xA;	NC_Pump.Curve = 	5&#xD;&#xA;&#xD;&#xA;80.000	NC_Pump.Flow = 	0.400 [µl/min]&#xD;&#xA;	NC_Pump.%B = 	45.0 [%]&#xD;&#xA;	NC_Pump.Curve = 	5&#xD;&#xA;&#xD;&#xA;85.000	NC_Pump.Flow = 	0.400 [µl/min]&#xD;&#xA;	NC_Pump.%B = 	95.0 [%]&#xD;&#xA;	NC_Pump.Curve = 	5&#xD;&#xA;&#xD;&#xA;90.000	NC_Pump.Flow = 	0.400 [µl/min]&#xD;&#xA;	NC_Pump.%B = 	95.0 [%]&#xD;&#xA;	NC_Pump.Curve = 	5&#xD;&#xA;&#xD;&#xA;90.500	NC_Pump.Flow = 	0.400 [µl/min]&#xD;&#xA;	NC_Pump.%B = 	5.0 [%]&#xD;&#xA;	NC_Pump.Curve = 	5&#xD;&#xA;&#xD;&#xA;92.000	ValveLeft = 	1_2&#xD;&#xA;&#xD;&#xA;97.000	NC_Pump.Flow = 	0.400 [µl/min]&#xD;&#xA;	NC_Pump.%B = 	5.0 [%]&#xD;&#xA;	NC_Pump.Curve = 	5&#xD;&#xA;	End&#xD;&#xA;    &lt;/ModuleInfo&gt; &#xD;&#xA;&#xD;&#xA;&#xD;&#xA;&lt;/root&gt;" xmlns="" />
  <Device Type="None" Number="0" xmlns="" />
  <Device Type="Pump" Number="1" FullName="Dionex System	SYSTEM1	PUMP	PLUGIN" xmlns="" />
  <Device Type="AutoSampler" Number="1" FullName="Dionex System	SYSTEM1	ALS	PLUGIN" xmlns="" />
  <Device Type="Detector" Number="1" FullName="Dionex System	SYSTEM1	DET	PLUGIN" xmlns="" />
  <Device Type="System" Number="1" FullName="Dionex System	SYSTEM1	SYS	PLUGIN" xmlns="" />
  <Device Type="MassSpec" Number="1" FullName="micrOTOF series	MS1	MS	LAN" xmlns="" />
</FractionTreatmentDataSet>